Note: 300 hours of operation is an approximate and can be done either before or slightly after 300 hours.
This procedure is in addition to maintenance required after each use in clean or dirty water.
If your LBV is fitted with the SBT150 brushed thrusters the motors will soon require rebuilding. Inside the thruster is a brushed motor with a graphite brush that wears out around 300 to 500 hours depending on the operating conditions. You will be able to identify when the motor brushes are worn by erratic thruster behavior.
It is recommended you send in your thrusters to SeaBotix or an authorized service center to have new motors installed. At the same time the O-rings are replaced and the thrusters are returned like they were new.
Contact your nearest authorized service center or SeaBotix to arrange for your thruster rebuild.
SeaBotix Service Contact Details:
SeaBotix Inc.
1425 Russ Blvd, T112D
San Diego, CA 92101
USA
Tel: +1 619 239 5959
Contact Person
Matthew Nerz
service@seabotix.com