Note: 500 hours of operation is an approximate and can be done either before or slightly after 500 hours.

This procedure is in addition to maintenance required after each use in clean or dirty water.

After 500 hours of operation or two (2) years it is recommended that your LBV system be sent in for an update and full sealing O-ring replacement. This procedure thoroughly checks over all the components of your LBV system, updates to the latest specification and ensures it is in perfect working order.

Depending on the last service there can be many updates. Once your LBV system is received an estimate for the work to be done is sent to you for approval.

Examples of updates and replacements:

  • All sealing O-rings replaced
  • Update software (if required)
  • Update electronics (if required)
  • Refresh thruster grease gallery
  • Refresh oil in HPDC thrusters (if fitted)

Suggested replacements (not required):

  • View port
  • Protective shell
  • Halogen lamp

Contact your nearest authorized service center or SeaBotix to arrange for your LBV 500 hour service.

SeaBotix Service Contact Details:

SeaBotix Inc.
1425 Russ Blvd, T112D
San Diego, CA 92101
USA

Tel: +1 619 239 5959

Contact Person
Matthew Nerz
service@seabotix.com



How Many Hours on My LBV?

In the Menus of the LBV you can view the number of hours your LBV has been Powered ON (red LED on controller illuminated).

  • Press PGRM key
  • Press 5 for Main Menu
  • Press 3 for Diagnostics
  • Press 3 for Hours Run

Which Thrusters do I Have?

It is very simple to identify your type of thrusters. Only the LBV150B2 or LBV150S2 systems are supplied with SBT150 thrusters. Looking at your thrusters if there is a tube coming out of the rear connector end cap then you have the HPDC150 thrusters, if there is a seal screw you have the SBT thrusters.


Need More Help?

Find an authorized service center near you.

Or contact the SeaBotix service department directly.

Service Contact Details


Generation 2 Upgrade

Has your LBV been upgraded to the latest Gen 2 specification? More than 100 improvements.

learn more


Software Update

Make sure your LBV has the latest software installed.

learn more



Home > Support > Maintenance > 500 Hours
Copyright © 2008 SeaBotix, Inc. All rights reserved. Legal Notice
FREE counter and Web statistics from sitetracker.com