Depth Data is Erroneous: Reads full-scale negative, or value does not change.
|
| Failure #1 |
Depth Data corrupted, or not converted properly. |
| Cause #1 |
Depth sensor failure |
| Fault Isolation #1 |
Ensure sensor is fully connected and verify erroneous Depth Data is still present. Disconnect sensor. Depth reading will change to some non-negative value and Temperature should read -9 deg. C or F. Depth Sensor is faulty, and must be replaced. |
|
| Need More Help? |
Find an authorized service center near you.