Depth Data is Erroneous: Reads full-scale negative, or value does not change.

Failure #1 Depth Data corrupted, or not converted properly.           
Cause #1

Depth sensor failure

Fault Isolation #1 Ensure sensor is fully connected and verify erroneous Depth Data is still present. Disconnect sensor. Depth reading will change to some non-negative value and Temperature should read -9 deg. C or F. Depth Sensor is faulty, and must be replaced.