Depth Value shifts to lesser value during deployment. ROV software version is 2.01 or earlier.
|
| Failure #1 |
Depth temperature compensation is incorrect. |
| Cause #1 |
Incorrect software algorithm. |
| Fault Isolation #1 |
Using the ‘Calibrate/Temperature’ menu, adjust Temperature until it climbs above 56 deg. F/13 deg. C. Verify that Depth shifts to greater, correct value. It is recommended that the LBV System be upgraded to Ver 2.02 or later. Please contact SeaBotix for details. Note: this failure can be worked-around by entering an artificially high Temperature value, since Depth information is (usually) more vital than water temperature. |
|
| Need More Help? |
Find an authorized service center near you.
Or contact the SeaBotix service department directly.
Service Contact Details
|
|