Sonar displays ‘Timeout’ when LBV is energized, or Sonar Sweep moves in steps/is irregular. This occurs with first-time use, or new computers.
|
| Failure #1 |
No/Poor communications between SPS/ICC and computer. |
| Cause #1 |
Port settings on computer are incorrect. |
| Fault Isolation #1 |
Please verify the following for the computer port to which the Sonar is connected: 115,200 baud, 8 data bits, 0 parity bits, 1 stop bit. Advanced port settings: FIFO buffers on, adjust transmit and receive buffers until optimum sweep is achieved.
If problem persists reduce baud rate to 57,600. |
|
| Related Systems |
All systems fitted with sonar.
|
| Need More Help? |
Find an authorized service center near you.
Or contact the SeaBotix service department directly.